High Pressure Ratio Regulator

High Pressure Ratio Regulator

Many manufacturing processes require precise control of high pressures. It’s not difficult to find high pressure mechanical regulators, but it can be very difficult to find electronic controllers that can handle more than 1,000 PSI…and most are designed for much lower pressure. With Proportion-Air’s high pressure ratio regulator assemblies, pressures up to 7,500 PSI (and more) can be controlled with only shop air. That means we can use our standard electronic pressure regulators as pilots, controlling dome pressure to a high pressure ratio regulator.

See below for the most common ratio assemblies we specify.

Request Quote

45:1 3D .STEP View & Download

QB2X_RG1262_DST

 

QB2X-RG1262-DST | 45:1 High Pressure Ratio Regulator

Most of our ratio regulating assemblies will employ the QB2X as an electronic pilot accepting direct feedback from our DST high pressure transducer. The RG1262 high pressure ratio regulator can control pressures from 0-5,000 PSI and has a 45 to 1 (dome pressure to outlet pressure) ratio. This means that 0-5,000 PSI can be electronically controlled with a QB2X calibrated 0-111 PSI (111 x 45 = 5,000), using only shop air.

 

Specifications

Max Inlet Pressure 6,000 PSI (413 bar)
Max Outlet Pressure 0-5,000 PSI (345 bar)
Ratio (dome:outlet) 45:1 or 15:1
Flow Coefficient, Cv 0.05
Pneumatic Connections 1/4″ NPT
Accuracy ±0.5% F.S.
Process Conditions Static or Dynamic

114:1 3D .STEP View & Download

QB2X_PA3016AL_DST

 

QB2X-PA3016AL-DST | 114:1 High Pressure Ratio Regulator

Most of our ratio regulating assemblies will employ the QB2X as an electronic pilot accepting direct feedback from our DST high pressure transducer. The PA3016AL high pressure ratio regulator can control pressures from 0-10,000 PSI and has up to a 114 to 1 (dome pressure to outlet pressure) ratio. This means that 0-10,000 PSI can be electronically controlled with a QB2X calibrated 0-88 PSI (88 x 114 = 10,000), using only shop air.

 Specifications

Max Inlet Pressure 10,000 PSI (690 bar)
Max Outlet Pressure 7,500 PSI (517 bar)
Ratio (dome:outlet) Depends on control pressure
Flow Coefficient, Cv 1.0  or 2.0
Pneumatic Connections 1/2″ or 9/16″ NPT
Accuracy ±0.5% F.S.
Process Conditions Static or Dynamic

REQUEST QUOTE

Only looking to replace or re-order? Please use this form

Most quotes within 6 hours of understanding your needs

High Pressure Ratio Regulator ultima modifica: 2017-12-18T11:16:24-04:00 da admin

Subscribe To Our Newsletter

Join our mailing list to receive the latest news and updates from our team.

You have Successfully Subscribed!

Share This