F-Series Mass Flow Transducer

The F-series Mass Flow Transducer is a fast response flow monitor for all noble gases. The F-series uses a differential pressure measurement of air flowing across an internal venturi. The analog electronic circuit converts the differential pressure to an electronic output that is linear to the mass flow rate of air passing through the venturi. The combination of differential pressure with analog electronics makes for a fast response flow measurement. The F-series mass flow transducer may be coupled to a variety of Proportion-Air electronic flow control valves to make a complete factory calibrated flow control package.

The F-Series is available in multiple port sizes (1/4″ to 1-1/2″) and 3 distinct models: FR, FP and FA – more information on each model below.

Request Quote

%

Accuracy ±

%

Repeatability ±

Max Flow (SCFM)

Max P1 (PSI)

F-Series Downloads & Links
Documents Links Downloads
Installation Guide F-Series_Schematic Symbol
Sales Brochure File Request Form
F-Series Downloads & Links
Documents
Installation Guide
Sales Brochure
Downloads
F-Series_Schematic Symbol
File Request Form
F-Series Technical Specifications
Max Inlet Pressure Accuracy Repeatability Lowest Measured Flow
150 PSI (10.34 Bar) ±4% F.S. ±0.25% F.S. 2 to 20 SCFH (0.94-9.4 LPM)
Port Size Durability Ambient Temps Media Temps
1/4″ to 1-1/2″ NPT (BSPP Available) Immune to shock & vibration (up to 20 Gs) 32-158°F (0-70°C) 32-122°F (0-50°C)
Turn-Down Ratio Filtration Lowest Measured Flow
10:1 (inquire about 20:1) 40 Micron 25 to 250 SCFM (708-7080 LPM)
F-Series Technical Specifications
Max Inlet Pressure
150 PSI (12 Bar)
Minimum Inlet Pressure
15 PSI (1 Bar)
Accuracy
±4% F.S.
Repeatability
±0.25% F.S.
Lowest Measured Range
2 to 20 SCFH (0.94-9.4 LPM)
Turn-Down Ratio
10:1 (Inquire about 20:1)
Port Size
1/4″ to 1-1/2″ NPT (BSPP Available)
Durability
Immune to shock & vibration (up to 20 Gs)
Ambient Temps
32-158°F (0-70°C)
Media Temps
32-122°F (0-50°C)
Temperature Sensitivity
0.25% / °C
Filtration
40 Micron
Protection Rating
IP65
Lowest Measured Range
25 to 250 SCFM (708-7080 LPM)

Three

Flow Transducer Models

with subtle differences and important implications

FR

PRESSURE REGULATED

FR Model | This F-series mass flow transducer is a pressure regulated flow monitor that provides flow measurement in real-time – less than 10ms. This model requires a known and fixed regulated supply pressure to maintain its calibration. By regulating the input pressure, the incoming density of the gas is known and the FR model output is calibrated for that density.

*Requires a known and regulated inlet pressure

FP

PRESSURE COMPENSATED

FP Model | This F-series flow monitor has a 2nd transducer that measures the absolute pressure of the incoming gas. This allows the unit to compensate for changes in gas density due to changes in pressure. The FP model can compensate from 50% to 100% of the maximum calibrated absolute supply pressure, as called out in the part number. 

*Need to know the max potential inlet pressure

FA

ATMOSPHERIC

FA Model | This F-series flow monitor must have its output port open to atmosphere to work properly. It is calibrated for the density of gas at atmosphere. The FA model is most commonly used to meter out gas in cylinder speed control applications. The FA model must be paired with an FQPV, FQB3 or FQB2 to control cylinder speed.

*Designed for cylinder speed control